Antimicrobial Effect of Film Dressing for Skin around the Catheter Insertion Site

  • KATO Yukiko
    Department of Infection Control and Prevention, Aichi Medical University Hospital
  • HAMADA Yukihiro
    Department of Infection Control and Prevention, Aichi Medical University Hospital
  • KURUMIYA Ai
    Department of Infection Control and Prevention, Aichi Medical University Hospital
  • OKAMAE Tomoko
    Department of Infection Control and Prevention, Aichi Medical University Hospital
  • TAKAHASHI Tomoko
    Department of Infection Control and Prevention, Aichi Medical University Hospital
  • SAKATA Miki
    Department of Infection Control and Prevention, Aichi Medical University Hospital
  • SUEMATSU Hiroyuki
    Department of Infection Control and Prevention, Aichi Medical University Hospital
  • YOSHIDA Eiji
    ALCARE Co., Ltd, Tokyo, Japan
  • NISHIYAMA Naoya
    Department of Infection Control and Prevention, Aichi Medical University Hospital
  • KOIZUMI Yusuke
    Department of Infection Control and Prevention, Aichi Medical University Hospital
  • YAMAGISHI Yuka
    Department of Infection Control and Prevention, Aichi Medical University Hospital
  • MIKAMO Hiroshige
    Department of Infection Control and Prevention, Aichi Medical University Hospital

Bibliographic Information

Other Title
  • 抗菌性フィルムドレッシング材が中心静脈カテーテル挿入患者の刺入部皮膚細菌叢に与える影響
  • コウキンセイ フィルムドレッシングザイ ガ チュウシン ジョウミャク カテーテル ソウニュウ カンジャ ノ シニュウブ ヒフ サイキンソウ ニ アタエル エイキョウ

Search this article

Abstract

<p>It is clear that bacterial flora of skin around the catheter insertion site would be associated with catheter related bloodstream infection (CRBSI). We evaluated the antibacterial effect of film dressings including Fixkit®・CV (ALCARE Co., Ltd. Tokyo, Japan), which was composed of a transparent film adhesion material and an antibacterial pad with zinc, for skin around the catheter insertion site. We compared the antibacterial film dressing Fixkit®・CV and non-zinc contained film dressing as randomized control trial in the Aichi Medical University Hospital. The protocol was reviewed and approved by a local institutional committee, and written informed consents were obtained before enrolling. Two hundred and two patients with central venous catheter were enrolled in this study; 102 for Fixkit®・CV and 100 for non-antibacterial film dressing. We performed a quantitative microbial examination for a skin area of 1 cm2 around the catheter insertion site after removing the dressing films. The rates of positive bacterial detection for Fixkit®・CV and non-antibacterial film dressing were 47.1% and 62.0%, respectively (p= 0.03). According to logistic regression analysis, body mass index (BMI), gender, and insertion site of central venous catheter (CVC) were significant factors to isolate bacteria from the skin around the catheter insertion site. Positive bacterial detection rates between patients with BMI >25 and <25 were 73.8% and 49.4%, respectively (p = 0.01). BMI was the most important factor for the number of bacteria of skin around the catheter insertion site. We conclude that antimicrobial dressings such as antibacterial pad with zinc would be able to decrease the risk of skin colonization around the catheter insertion site in patients with BMI<25.</p>

Journal

References(18)*help

See more

Details 詳細情報について

Report a problem

Back to top