Antimicrobial Effect of Film Dressing for Skin around the Catheter Insertion Site
-
- KATO Yukiko
- Department of Infection Control and Prevention, Aichi Medical University Hospital
-
- HAMADA Yukihiro
- Department of Infection Control and Prevention, Aichi Medical University Hospital
-
- KURUMIYA Ai
- Department of Infection Control and Prevention, Aichi Medical University Hospital
-
- OKAMAE Tomoko
- Department of Infection Control and Prevention, Aichi Medical University Hospital
-
- TAKAHASHI Tomoko
- Department of Infection Control and Prevention, Aichi Medical University Hospital
-
- SAKATA Miki
- Department of Infection Control and Prevention, Aichi Medical University Hospital
-
- SUEMATSU Hiroyuki
- Department of Infection Control and Prevention, Aichi Medical University Hospital
-
- YOSHIDA Eiji
- ALCARE Co., Ltd, Tokyo, Japan
-
- NISHIYAMA Naoya
- Department of Infection Control and Prevention, Aichi Medical University Hospital
-
- KOIZUMI Yusuke
- Department of Infection Control and Prevention, Aichi Medical University Hospital
-
- YAMAGISHI Yuka
- Department of Infection Control and Prevention, Aichi Medical University Hospital
-
- MIKAMO Hiroshige
- Department of Infection Control and Prevention, Aichi Medical University Hospital
Bibliographic Information
- Other Title
-
- 抗菌性フィルムドレッシング材が中心静脈カテーテル挿入患者の刺入部皮膚細菌叢に与える影響
- コウキンセイ フィルムドレッシングザイ ガ チュウシン ジョウミャク カテーテル ソウニュウ カンジャ ノ シニュウブ ヒフ サイキンソウ ニ アタエル エイキョウ
Search this article
Abstract
<p>It is clear that bacterial flora of skin around the catheter insertion site would be associated with catheter related bloodstream infection (CRBSI). We evaluated the antibacterial effect of film dressings including Fixkit®・CV (ALCARE Co., Ltd. Tokyo, Japan), which was composed of a transparent film adhesion material and an antibacterial pad with zinc, for skin around the catheter insertion site. We compared the antibacterial film dressing Fixkit®・CV and non-zinc contained film dressing as randomized control trial in the Aichi Medical University Hospital. The protocol was reviewed and approved by a local institutional committee, and written informed consents were obtained before enrolling. Two hundred and two patients with central venous catheter were enrolled in this study; 102 for Fixkit®・CV and 100 for non-antibacterial film dressing. We performed a quantitative microbial examination for a skin area of 1 cm2 around the catheter insertion site after removing the dressing films. The rates of positive bacterial detection for Fixkit®・CV and non-antibacterial film dressing were 47.1% and 62.0%, respectively (p= 0.03). According to logistic regression analysis, body mass index (BMI), gender, and insertion site of central venous catheter (CVC) were significant factors to isolate bacteria from the skin around the catheter insertion site. Positive bacterial detection rates between patients with BMI >25 and <25 were 73.8% and 49.4%, respectively (p = 0.01). BMI was the most important factor for the number of bacteria of skin around the catheter insertion site. We conclude that antimicrobial dressings such as antibacterial pad with zinc would be able to decrease the risk of skin colonization around the catheter insertion site in patients with BMI<25.</p>
Journal
-
- Japanese Journal of Infection Prevention and Control
-
Japanese Journal of Infection Prevention and Control 32 (2), 67-73, 2017
Japanese Society for Infection Prevention and Control
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680273668096
-
- NII Article ID
- 130005655722
-
- NII Book ID
- AA12313188
-
- ISSN
- 18832407
- 1882532X
-
- NDL BIB ID
- 028091135
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed