A case of neurofibromatosis type 1 with ruptured extracranial giant internal carotid aneurysm—usefulness of 4Fr inner catheter for endovascular trapping of internal carotid artery—

  • OKAMOTO Soushi
    Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
  • KUBO Michiya
    Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
  • HAYASHI Tomohide
    Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
  • HORI Satoshi
    Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
  • HORI Emiko
    Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
  • SHIBATA Takashi
    Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
  • HORIE Yukio
    Department of Neurosurgery, Stroke Center, Saiseikai Toyama Hospital
  • KUWAYAMA Naoya
    Department of Neurosurgery, University of Toyama
  • KURODA Satoshi
    Department of Neurosurgery, University of Toyama

Bibliographic Information

Other Title
  • 神経線維腫症1 型(NF-1)に合併した破裂頭蓋外巨大内頚動脈瘤の一例—4Fr インナーカテーテル併用による endovascular trapping 安定性・安全性の向上—
  • 症例報告 神経線維腫症1型(NF-1)に合併した破裂頭蓋外巨大内頚動脈瘤の一例 : 4Frインナーカテーテル併用によるendovascular trapping安定性・安全性の向上
  • ショウレイ ホウコク シンケイ センイ シュショウ 1ガタ(NF-1)ニ ガッペイ シタ ハレツ ズガイ ガイ キョダイ ナイ ケイ ドウミャクリュウ ノ イチレイ : 4Fr インナーカテーテル ヘイヨウ ニ ヨル endovascular trapping アンテイセイ ・ アンゼンセイ ノ コウジョウ
  • A case of neurofibromatosis type 1 with ruptured extracranial giant internal carotid aneurysm^|^mdash;usefulness of 4Fr inner catheter for endovascular trapping of internal carotid artery^|^mdash;

Search this article

Abstract

Objective: We report a case of neurofibromatosis type 1 with ruptured extracranial giant internal carotid artery (ICA) aneurysm, treated by endovascular trapping using a triple coaxial catheter system.<br>Case presentation: A 41-year-old female presented with dysphagia, and acutely appeared and enlarged left neck mass. Cerebral angiography, MRI, and contrast CT revealed ruptured extracranial giant ICA aneurysm. Since urgent treatment was necessary, endovascular coil-trapping was planned, considering the vulnerable aneurysmal wall. Initially, a microcatheter was easily kicked back and fallen down into the aneurysm during coil placement of the distal ICA. Next, we tried it with triple coaxial catheter system, using 4Fr inner catheter and balloon guiding catheter, which made the procedure of the distal and proximal ICA trapping stable and easy. Endovascular trapping was finished successfully and her symptoms were improved.<br>Conclusion: A triple coaxial catheter system was considered to be effective in endovascular trapping for treatment of a giant aneurysm with coils.

Journal

Citations (2)*help

See more

References(9)*help

See more

Details 詳細情報について

Report a problem

Back to top