WATERTIGHTNESS BEHAVIOR OF PRECAST REINFORCED CONCRETE MEMBERS JOINED WITH CAST IRON COUPLERS
-
- TSUJI Yukikazu
- JAPAN SOCIETY OF CIVIL ENGINEERS
-
- SUHARA Kentaro
- JAPAN SOCIETY OF CIVIL ENGINEERS
-
- MORITA Toshiya
- JAPAN SOCIETY OF CIVIL ENGINEERS
Bibliographic Information
- Other Title
-
- 鋳鉄製カップラー接合具で接合したプレキャストRC部材の水密性状
- チュウテツセイ カップラー セツゴウグ デ セツゴウ シタ プレキャスト RC ブザイ ノ スイミツ セイジョウ
Search this article
Abstract
The cast iron coupler combined with two anchor bars is a joint device that can connect with two precast reinforced concrete elements easily and mechanically. In order to examine watertightness behavior of the joint with which two reinforced concrete beams were joined, tests for watertightness were carried out by a water-pressuring method. It was shown that watertightness of the joint was satisfacticable at service loading levels. And, the cast iron couplers can be used for precast reinforced concrete members even under the ground level.