FATIGUE STRENGTH OF OUT-OF-PLANE GUSSET TREATED BY ULTRASONIC NEEDLE PEENING WITH A SMALL RADIUS TIP PIN

Bibliographic Information

Other Title
  • 先端曲率半径が小さいUltrasonic Needle Peeningを施した面外ガセットの疲労強度

Description

Effect of high frequency peening treatment with a small radius tip pin, which is less than 3mm radius tip pin, still remains unclear, although the effect of ultrasonic impact treatment on fatigue strength has been investigated. The objective of this study is to investigate the effect of ultrasonic needle peening with a 1.5mm radius tip pin on fatigue strength of out-of-plane gusset by using bending fatigue tests. The results show that the treatment can improve fatigue strength, when mean stress is not changed after the treatment is carried out. It also shows that the effect of the treatment become less with increasing mean stress after the treatment is carried out, and when the treatment is not sufficient at weld toe.

Journal

  • Kou kouzou rombunshuu

    Kou kouzou rombunshuu 21 (83), 11-18, 2014

    Japanese Society of Steel Construction