Development of an integration circuit to measure pulsed magnetic field: evaluation of its usefulness by comparing measured with theoretical magnetic field structure

  • Izumi Shin-Ichi
    Department of Physical Medicine and Rehabilitation, Tohoku University Graduate School of Biomedical Engineering Department of Physical Medicine and Rehabilitation, Tohoku University Graduate School of Medicine
  • Oouchida Yutaka
    Department of Physical Medicine and Rehabilitation, Tohoku University Graduate School of Medicine
  • Okita Taishi
    Institute of Fluid Science, Tohoku University
  • Suzuki Eizaburo
    Department of Physical Medicine and Rehabilitation, Tohoku University Graduate School of Medicine
  • Abe Toshihiko
    IFG Co.,Ltd
  • Nagatomi Ryoichi
    Laboratory of Health and Sports Science, Tohoku University Graduate School of Biomedical Engineering
  • Nakasato Nobukazu
    Department of Epileptology, Tohoku University Graduate School of Medicine
  • Takagi Toshiyuki
    Institute of Fluid Science, Tohoku University

Search this article

Description

Izumi S, Oouchida Y, Okita T, Suzuki E, Abe T, Nagatomi R, Nakasato N, Takagi T. Development of an integration circuit to measure pulsed magnetic field: evaluation of its usefulness by comparing measured with theoretical magnetic field structure. Jpn J Compr Rehabil Sci 2012; 3: 42-50. <BR>Objective: To develop a search coil with a capacity-resistor (CR) integration circuit for instantaneous measurement of a pulsed magnetic field, and to compare the magnetic field structure measured by the novel device with the theoretical values. <BR>Methods: <FONT COLOR="#231f20">The integration circuit consists of a capacitor and a resistor connected in series, and generates a voltage output across the capacitor. For magnetic field measurement, we selected capacitance × resistance = 4 ms. Using the search coil and CR integration circuit, we measured the magnetic flux density generated by a circular coil, over a range of magnetic flux densities (0.1 to 1.4 T) and pulse widths (0.1 to 0.6 ms). We also obtained the corresponding magnetic fields by numerical integration of the electromotive force induced in the search coil. Then we measured the distribution of magnetic flux densities generated by a commercial figure-of-eight coil commonly used in transcranial magnetic stimulation (TMS), and compared the results with the magnetic field derived from model calculation. <BR>Results: The values measured by the CR circuit and the values obtained by numerical integration showed good agreement (R2=0.9993). At 100% output from the stimulator, the peak magnetic flux density of the horizontal and vertical magnetic fields at a distance 10-30 mm from the figure-of-eight coil surface was 0.2 to 0.5 T. The measured magnetic field showed less focalization when compared with the values obtained from model calculation. <BR>Conclusions: We identified the appropriate CR combination for the integration circuit used to measure a pulsed magnetic field. This device would be useful for quantitative analysis of TMS-induced effects on cortical function.

Journal

Citations (2)*help

See more

References(16)*help

See more

Details 詳細情報について

Report a problem

Back to top