- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Cardiovascular Effects of Dibutyryl cyclic AMP During Nitrous Oxide Halothane Anesthesia
-
- NOZAKI Hirofumi
- Department of Anesthesiology, Fukushima Medical College
-
- MINOGUCHI Yoichi
- Department of Anesthesiology, Fukushima Medical College
-
- SHOH Korin
- Department of Anesthesiology, Fukushima Medical College
-
- INOUE Toshiyuki
- Department of Anesthesiology, Fukushima Medical College
-
- SUZUKI Mihoko
- Department of Anesthesiology, Fukushima Medical College
-
- OKUAKI Akira
- Department of Anesthesiology, Fukushima Medical College
Bibliographic Information
- Other Title
-
- Halothane, 笑気麻酔時, Dibutyryl cyclic AMPの心拍出量および血糖値に及ぼす影響
Search this article
Description
The effects of dibutyryl cyclic AMP (db-cAMP) on cardiovascular hemodyna-mics and changes in blood sugar and serum insulin levels were evaluated in GOF-anesthetized man. Observations were made on 15 patients of both sexes and ranging in age from 24 to 63 yrs who were to undergo surgery. Sixty minutes before induction, each patient was given a moderate dose of atropine as preme-dications. Stroke volume and cardiac output were measured by a Minnesota impedance cardiograph, arterial blood pressure was measured by auscultation, total peripheral resistance was calculated from the mean arterial pressure and cardiac output, the heart rate was obtained from an ECG monitor, blood sugar and serum insulin levels were determined from venous blood, and the insulin-glucose ratio was calculated from the insulin and blood sugar levels. Twenty minutes after GOF anesthesia, 5mg/kg of db-cAMP were injected and its effects were studied for 30 minutes prior to surgery with the following results:<BR>1) Db-cAMP increased the heart rate slightly and lowered systolic and diastolic pressure while increasing pulse pressure slightly.<BR>2) Both the stroke volume and cardiac output increased after db-cAMP injec-tion.<BR>3) Total peripheral resistance decreased remarkably after db-cAMP injection.<BR>4) Blood sugar and serum insulin levels both increased remarkably, with a slight increase in the insulin-glucose ratio after db-cAMP administration.
Journal
-
- Rinsho yakuri/Japanese Journal of Clinical Pharmacology and Therapeutics
-
Rinsho yakuri/Japanese Journal of Clinical Pharmacology and Therapeutics 11 (1), 65-70, 1980
The Japanese Society of Clinical Pharmacology and Therapeutics
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680344081920
-
- NII Article ID
- 130002048227
-
- ISSN
- 18828272
- 03881601
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed