STABILITY CONDITION OF SURGE TANK (1st Report)

DOI
  • Homma M.
    社團法人土木學會 東京大学第一工学部
  • Hayashi T.
    社團法人土木學會 東京大学第一工学部

Bibliographic Information

Other Title
  • 調圧水槽の安定条件について (第1報)

Abstract

This paper discribes about the stability condition of surge tank.<br>To survey theoretically how inertia and resistance of penstock and inertia of rotation parts of turbin and generator and inertia of other generator that is parallel operated exert influence on stability of surge tank.<br>From these elements, general stability conditions are described, and from the result of this study, in case of the generator that is connected at surge tank is parallel operated, necessary surge tank section area is most smaller than the section which is comperted from the methods of Thoma condition.