A study on stress corrosion cracking and corrosion fatigue of rolled 7075 aluminum alloy.
-
- SUZUKI Megumu
- Faculty of Engineering and Design, Kyoto Institute of Technology
-
- AWOTANI Toshiaki
- Kyoto Institute of Technology
-
- NAKANISHI Hiroshi
- Faculty of Engineering and Design, Kyoto Institute of Technology
-
- OKAZAKI Shozo
- Technical Institute, Kawasaki Heavy Industries
-
- HASEGAWA Kiyoshi
- Technical Institute, Kawasaki Heavy Industries
-
- MATSUDA Shozo
- Technical Institute, Kawasaki Heavy Industries
-
- NAKAMURA Hiroshi
- Technical Institute, Kawasaki Heavy Industries
Bibliographic Information
- Other Title
-
- アルミニウム合金7075圧延材の応力腐食割れと腐食疲労に関する研究
- アルミニウム ゴウキン 7075 アツエンザイ ノ オウリョク フショク ワレ
Search this article
Description
Stress corrosion cracking (SCC) and corrosion fatigue (CF) experiments were performed on the test specimens in three directions (L, LT, ST) of rolled 7075 aluminum alloy. The results obtained are as follows.<br>(1) The SCC life time of the test specimen in ST direction could be estimated from the applied stress, the tensile strength, and the activation energy which is determined by changing the temperature of corrosive solution and immersing the test specimen in LT direction.<br>(2) There was a combined effect of SCC and CF in CF experiments for the test specimen in LT direction, because the total accumulated damage factor was smaller than one when the linear damage summation method was applied to the experimental result of CF at 5min. stress hold time. This effect was confirmed on the fracture surface of the test specimen.<br>(3) However, the effect was not observed either in the CF experimental result or on the fractograph for the specimen in L direction tested at room temperature and 30min. stress hold time, nor for the specimen in ST direction tested at 70°C and 5min. stress hold time.
Journal
-
- Journal of the Society of Materials Science, Japan
-
Journal of the Society of Materials Science, Japan 35 (393), 647-653, 1986
The Society of Materials Science, Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680369941632
-
- NII Article ID
- 110002296834
-
- NII Book ID
- AN00096175
-
- ISSN
- 18807488
- 05145163
-
- NDL BIB ID
- 3096030
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed