A STUDY OF RATIONAL VENTILATION FORM FOR A CONSTRUCTING HUGE TUNNEL
-
- HAYASAKA Harutoshi
- 日本鉄道建設公団北陸新幹線第二建設局朝日鉄道建設所
-
- SAKATA Kazuyuki
- ハザマ北陸支店新親不知トンネル作業所
-
- SINO Kazumi
- ハザマ北陸支店新親不知トンネル作業所
-
- SUZUKI Masayuki
- ハザマ土木本部トンネル統括部
-
- ARAKIDA Ken
- ハザマ土木本部トンネル統括部
Bibliographic Information
- Other Title
-
- 長大トンネルにおける合理的な換気手法の検討
Abstract
SIN-OYASHIRAZU tunnel is huge tunnel 5, 229m long. On the huge tunnel, the work environment gets bad, as evidenced by increaseing the dump truck and air leaking of ventilation ducts. Therefore, excessive ventilation equipment becomes necessary, and a construction fee rises to secure a good working environment. As for this tunnel, a rational ventilation form was examined, long ventiletion ducts and a container system were adopted as a result of the examination. This report about the examination of the rational ventilation form and the result.
Journal
-
- PROCEEDINGS OF TUNNEL ENGINEERING, JSCE
-
PROCEEDINGS OF TUNNEL ENGINEERING, JSCE 8 261-264, 1998
Japan Society of Civil Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680378919936
-
- NII Article ID
- 130004387414
-
- ISSN
- 18849091
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed