試作した衝撃ねじり試験機とそれによる二, 三の低温ねじり試験結果について

書誌事項

タイトル別名
  • Some Torque-Twist Relations on the Low Temperature Dynamic Torsion Test of Low Carbon Steel
  • シサク シタ ショウゲキネジリ シケンキ ト ソレニ ヨル ニ , サン ノ テイオンネジリ シケン ケッカ ニ ツイテ

この論文をさがす

抄録

The present investigation was carried out for the size effects of test piece and various testing conditions on the torsional fracture behaviour, using a newly developed dynamic torsion machine. Dynamic torque-twist curves were obtained photographically at various temperatures. The maximum rate of straining was 60per second and the range of temperatures from +200°C to -196°C.<br>Yield and fracture strength and plastic strain to fracture were not affected by the variation of gauge length of the test piece, but yield and fracture strength increased with decreasing of the diameter. The size effects on torsional strength were also appeared for hollowed specimens as well as for solid ones. In the static torsion test, farcture type at comparatively low temperature had a ductile manner and the cleavage fracture appeared only at -196°C under the tested conditions. On the other hand, in the dynamic test, the specimens used for the investigation took a ductile fracture, excepting a specimen having a larger grain than the A.S.T.M. No 4.<br>The torque-twist curves in static test or room temperature dynamic test dropped at maximum torque after drop in load. To the contrary, in the low temperature dynamic test, after reaching the maximum stress, torque suddenly decreased with increasing twist angle and then kept a constant value until the beginning of fracture. Ruptured specimen with cleavage type due to the dynamic torsion test had been broken at maximum torque. These strange phenomena in the fracture manners and the torque-twist curves were discussed and assumed to be due to the temperature rise in the tested part connected with the rapid large plastic deformation.

収録刊行物

  • 材料

    材料 12 (117), 457-463, 1963

    公益社団法人 日本材料学会

被引用文献 (1)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ