- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Combination Use of the Laser Surgical Unit and the Ultrasonic Surgical Aspirator
-
- TAKIZAWA Toshiaki
- Department of Neurosurgery, Central Hospital of the Japanese National Railways
-
- YAMAZAKI Takashi
- Department of Neurosurgery, Central Hospital of the Japanese National Railways
-
- MATSUMOTO Masahisa
- Department of Neurosurgery, Central Hospital of the Japanese National Railways
-
- MOCHIDA Nobuo
- Medical Electronics Division, Mochida Pharmaceutical Company, Ltd.
-
- TOGO Takashi
- Medical Electronics Division, Mochida Pharmaceutical Company, Ltd.
-
- TAKEUCHI Kazumasa
- Medical Electronics Division, Mochida Pharmaceutical Company, Ltd.
-
- MORO Akio
- International Medical Intel ligence (IMI) Company, Ltd.
Bibliographic Information
- Other Title
-
- レーザーメスと超音波吸引器の併用
Search this article
Description
We performed surgery on 11 cases of brain tumor using the CO2 laser surgical unit in combination with the ultrasonic surgical aspirator. The CO2 laser scalpel which we used is the Medilaser-S Model MEL-442 which was developed by T. Takizawa and his team for neurosurgery. And the ultrasonic surgical aspirator which we used is the Cavitron Ultrasonic Surgical Aspirator (CUSA) which was developed by E. S. Flamm. The CO2 laser scalpel can bloodlessly vaporize brain tumor with minimal damage to the neural tissue surrounding the tumor. But in cases where the vital arteries or veins run through the tumor, it is very dangerous to vaporize the tumor tissue blindly because this might lead to an inadvertent lasing of vital blood vessels. In such cases, the CUSA system is very useful because it leaves the arteries intact during removal of tumor tissue. In this paper the the surgical techniques to remove brain tumors using the CO2 laser scalpel in combination with the CUSA system are shown together with the 16 mm movie film and the slides. The advantages and disadvantages of the CO2 laser scalpel and the CUSA system are discussed in the case presentation.
Journal
-
- The Journal of Japan Society for Laser Surgery and Medicine
-
The Journal of Japan Society for Laser Surgery and Medicine 1 (1), 259-268, 1980
Japan Society for Laser Surgery and Medicine
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680432824320
-
- NII Article ID
- 130004702138
-
- ISSN
- 02886200
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed