Design and Construction of High-rise Reinforced Concrete Building with Precast Reinforced Concrete Members Cast on The Construction Site by High Strength Concrete of <I>F<SUB>c</SUB></I>=600 kgf/cm2 and High Strength Reinforcement of SD 490.
-
- Fujii T.
- (株) 大林組本店建築工務部
-
- Tamai S.
- (株) 大林組阪急土室工事事務所
-
- Nishimura K.
- (株) 大林組本店建築設計第7部
-
- Shimizu F.
- (株) 大林組本店建築工務部
Bibliographic Information
- Other Title
-
- <I>F<SUB>c</SUB></I>=600 kgf/cm2の高強度コンクリートとSD 490 の高強度鉄筋を用いたサイトPCa部材による高層RC造建物の設計・施工
- Design and Construction of High-rise Reinforced Concrete Building with Precast Reinforced Concrete Members Cast on The Construction Site by High Strength Concrete of Fc=600 kgf/cm2 and High Strength Reinforcement of SD 490.
- 阪急ヒルズコート高槻7番館
Search this article
Description
Hankyu Hills Court Takatsuki 7 th is a 20 story high-rise reinforced concrete building which is used for condominium. We designed and constructed it by using the high strength concrete of Fc=600 kgf/cm2 and the high strength reinforcement of SD 490. Introducing these materials, we made it possible to reduce the section of columns and beams, and to decrease a number of reinforcement. We developed and made practicable the structural system 0. P. C. S. (OBAYASHI Progressive Concrete System) using precast reinforced concrete members cast on the construction site and to joint the horizontal reinforcement of beam in the beam-columnjoint. As a result of the above mentioned method, we have gotten the satisfactory results ; high constructability, shorter construction period, reduced resource requirements, and high quality. This report describes the design and structural system of precast reinforced concrete members cast on the construction site using the high strength concrete of Fc=600 kgf/cm2 and the high strength reinforcement of SD 490, and the concrete work and quality control for the high strength concrete of 600 kgf/cm2.
Journal
-
- Concrete Journal
-
Concrete Journal 33 (4), 45-54, 1995
Japan Concrete Institute
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680432903936
-
- NII Article ID
- 10001647652
-
- NII Book ID
- AN00094169
-
- ISSN
- 03871061
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed