- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Measurement of the Internal Shoulder Rotation Angle with the Elbow Extended
-
- HORII Motoyuki
- Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine
-
- YAMAGUCHI Junko
- Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine
-
- MORIHARA Toru
- Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine
-
- ISHIDA Masashi
- Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine
-
- OKUMURA Hisashi
- Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine
-
- KUBO Toshikazu
- Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine
-
- KUROKAWA Masao
- Department of Orthopaedic Surgery, Saiseikai Suita Hospital
Bibliographic Information
- Other Title
-
- 肘伸展位での肩関節内旋角度測定の試み
Search this article
Description
The aim of this study was to devise a measurement method for the shoulder internal rotation with the elbow being extended using special plates that we developed, and compared the measured angles with those of conventional measurements. The subjects were 20 healthy volunteers (40 shoulders). In our new method, a rod was applied to the front of the elbow, and the internal rotation angles were measured using the plates with the elbow being extended, As the conventional method, internal rotation was expressed as thumb-distance from Jacoby's line. In addition, the external rotation angles were measured conventionally with the elbow flexed. Measurements were taken 3 times, each in the unit of 5 degrees or 1 cm in the sitting position. The angle of internal rotation was 80-120°in the new method and 17-41cm in the conventional method; there was a correlation (p<0.001), with a correlation coefficient of O.645. The differences of the values in the three times measurements were 0°(no difference) in 19 shoulders and 5°in 21 shoulders in the new measurement of the internal rotation. In the conventional measurement of the external rotation, tie difference was 0°,5°and 10°in 22,17 and 1 shoulder, respectively. The measurement of the shoulder internal rotation with elbow extended was easy to achieve, and the differences of the values in the three times measurements were almost identical with those of the conventional measurement of the shoulder external rotation. The new method is useful for measuring the range of internal shoulder rotation.
Journal
-
- Katakansetsu
-
Katakansetsu 29 (3), 479-481, 2005
Japan Shoulder Society
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680445013760
-
- NII Article ID
- 130004644113
-
- ISSN
- 09104461
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed