- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Usefulness of the STATAK in a Bankart Repair and Modified Bristow Procedure for Recurrent Anterior Dislocation of the Glenohumeral Joint.
-
- KIMURA Akihiko
- Department of Orthopaedic Surgery Sapporo Medical University
-
- OKAMURA Kenji
- Department of Orthopaedic Surgery Sapporo Medical University
-
- FUKUSHIMA Sunao
- Department of Orthopaedic Surgery Sapporo Medical University
-
- NAGAMORI Masasi
- Department of Orthopaedic Surgery Sapporo Medical University
-
- AOKI Mitsuhiro
- Department of Orthopaedic Surgery Sapporo Medical University
-
- USUI Masamichi
- Department of Orthopaedic Surgery Sapporo Medical University
-
- ISHII Seiichi
- Department of Orthopaedic Surgery Sapporo Medical University
-
- HOTTA Tomonobu
- Department of Orthopaedic Surgery, Otaru Hokusei Hospital
Bibliographic Information
- Other Title
-
- 反復性肩関節前方脱臼に対するBankartおよびmodified Bristow法合併手術におけるSTATAKの有用性
Search this article
Description
[Purpose]To investigate whether STATAK is useful in Bankart repair&modified Bristow procedure (: B&B).<BR>[Materials and Methods]Forty patients with recurrent anterior dislocation with severe bone defects of the anterinferior glenoid border underwent surgery by B&B with STATAK (group S). The 43 patients who underwent surgery with a conventional bone tunnel suture were the control group (group B). We investigated the clinical results by using the Rowe's scoring system and operation time of both groups and the failure of STATAK insertion.<BR>[Results]The average of Rowe's score was 92.8 in group S, and 92.5 in group B, and there was no significant difference in either group. The average of operation time including arthroscopic examination was shorter by about five minutes in group S than in group B. The failure ratio of STATAK insertion was 6.3% of all 128 anchors. The modes of failure were four anchor pullouts, one anchor cut out, and three suture cutouts.<BR>[Discussion]Under accurate management a STATAK insertion will be useful in B&B for recurrent anterior dislocation of the glenohumeral joint with severe bone defect of the anteroinferior glenoid bo rder.
Journal
-
- Katakansetsu
-
Katakansetsu 23 (2), 333-337, 1999
Japan Shoulder Society
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680445699072
-
- NII Article ID
- 10013377256
-
- NII Book ID
- AN10040891
-
- ISSN
- 09104461
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed