- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Measurement of Mean Arteria Pressure in Rats by a Tail-cuff Method with Sensitive Photoelectric Sensors
-
- SAKAMAKI Tetsuo
- <I>Second Department of Internal Medicine, Gunma University School of Medicine</I>
-
- TAJIMA Yoshihiro
- <I>Second Department of Internal Medicine, Gunma University School of Medicine</I>
-
- ICHIKAWA Shuichi
- <I>Second Department of Internal Medicine, Gunma University School of Medicine</I>
-
- MURATA Kazuhiko
- <I>Second Department of Internal Medicine, Gunma University School of Medicine</I>
Bibliographic Information
- Other Title
-
- テールカフ法によるラットの平均血圧測定の信頼性
- テールカフ法によるラットの平均血圧測定の信頼性〔英文〕
- テールカフホウ ニ ヨル ラット ノ ヘイキン ケツアツ ソクテイ ノ シンラ
Search this article
Description
We evaluated a recently developed tail-cuff apparatus containing sensitive photoelectric sensors in the measurement of arterial pressure in rats. A total of 48 male Wistar rats were used in the study. The indirect mean arterial pressure (MPi) was determined from the cuff pressure when the pulse volume oscillations were maximal. To create sufficiently large pulse volume oscillations, we heated the rats for about 12 minutes at 38°C prior to recording the pressure. The heating increased the mean arterial pressure by an average of 4±2 mmHg, as indicated by direct measurement of pressure. Three different sizes of cuffs were tested, with the result that the indirect measurements were nearly identical to those obtained directly when an appropriate cuff size was selected. The MPi was well correlated with the direct measurement of mean arterial pressure before (r=0.918, p<0.001) and during (r=0.903, p<0.001) elevation of arterial pressure via norepinephrine infusion. These results indicate that the MPi determined at maximum pulse volume oscillations coincides fairly well with the true mean arterial pressure.
Journal
-
- Experimental Animals
-
Experimental Animals 36 (4), 409-414, 1987
Japanese Association for Laboratory Animal Science
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680478941056
-
- NII Article ID
- 130005000630
- 130006134818
-
- NII Book ID
- AN00104954
-
- ISSN
- 18817122
- 00075124
-
- NDL BIB ID
- 3174525
-
- PubMed
- 3436374
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed