- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
-
- MAEYAMA Takuya
- Department of Chemistry, School of Science, Kitasato University
Bibliographic Information
- Other Title
-
- フリッケゲル線量計
- フリッケゲルセンリョウケイ
Search this article
Description
<p>Fricke gel dosimeters are based on the aqueous ferrous sulfate solution that has been used as a reliable chemical dosimeter for more than 90 years. The amount of radiation-induced oxidation of ferrous ions to ferric ions could be evaluated three-dimensionally via optical computed tomography (OCT) or magnetic resonance imaging (MRI). Three-dimensional dosimetry is expected to be a useful tool, in particular, for the verification of complex radiation dose planning in advanced radiation cancer therapy. Compared with other 3D gel dosimeters, there are several problems such as retention of dose distribution or dose sensitivity; however, they can easily be prepared in a chemistry laboratory. In addition, a unique gel dosimeter was also reported for heavy-ion beam irradiation. In this review, recent papers concerning the Fricke gel dosimeter and its application in 3D dosimetry are summarized.</p>
Journal
-
- Japanese Journal of Medical Physics (Igakubutsuri)
-
Japanese Journal of Medical Physics (Igakubutsuri) 37 (2), 99-106, 2017
Japan Society of Medical Physics
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680486582784
-
- NII Article ID
- 130006943057
-
- NII Book ID
- AA11580542
-
- ISSN
- 21869634
- 13455354
-
- NDL BIB ID
- 028623573
-
- PubMed
- 29151472
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- PubMed
- CiNii Articles
- KAKEN
- OpenAIRE
-
- Abstract License Flag
- Disallowed