Element-selective visualization for materials science using synchrotron X-ray two-wavelength anomalous powder diffraction data
-
- Nishibori Eiji
- Division of Physics, Faculty of Pure and Applied Sciences, Tsukuba Research Center for Interdiscriplinary Materials Science (TIMS) & Center for Integrated Research in Fundamental Science and Engineering (CiRfSE), University of Tsukuba RIKEN SPring-8 Center, RIKEN
-
- Takata Masaki
- RIKEN SPring-8 Center, RIKEN
説明
Algorithms for determining the element-selective charge density are developed using two-wavelength anomalous synchrotron X-ray powder diffraction (MAPD) data. We have reported that an algorithm of element-selective charge density study from three wavelengths MAPD using near K absorption edge. The present study, we developed an algorithm from two wavelengths MAPD using near LIII absorption edge. The method is employed in order to investigate a large anharmonic thermal vibration of Gold atom in Gold metal complex, Au(tmdt)2 (tmdt: trimethylene- tetrathiafulvalene-dithiolate).