Influence of Light Irradiation on the Early Bonding Characteristics of Self-adhesive Resin Cements

DOI
  • KUROKAWA Hiroyasu
    Department of Operative Dentistry, Nihon University School of Dentistry:Division of Biomaterials Science, Dental Research Center, Nihon University School of Dentistry
  • TAKIMOTO Masayuki
    Department of Operative Dentistry, Nihon University School of Dentistry
  • SHIRATSUCHI Koji
    Department of Operative Dentistry, Nihon University School of Dentistry
  • IINO Masayoshi
    Department of Operative Dentistry, Nihon University School of Dentistry
  • ISHII Ryo
    Department of Operative Dentistry, Nihon University School of Dentistry
  • TAKENAKA Hirotaka
    Department of Operative Dentistry, Nihon University School of Dentistry
  • SUZUKI Takayuki
    Department of Operative Dentistry, Nihon University School of Dentistry
  • YAMAJI Ayumi
    Department of Operative Dentistry, Nihon University School of Dentistry
  • MIYAZAKI Masashi
    Department of Operative Dentistry, Nihon University School of Dentistry:Division of Biomaterials Science, Dental Research Center, Nihon University School of Dentistry

Bibliographic Information

Other Title
  • 光線照射が自己接着性レジンセメントの初期接着挙動に及ぼす影響

Search this article

Abstract

Purpose: Self-adhesive resin cements (SARCs) have been marketed to simplify clinical procedures and overcome the technique sensitivity of multiple-step systems. However, the dentin bonding performance under different light irradiation conditions of the cement is not known. This study monitored the chronological change of dentin bond strengths of SARCs. Methods: Three SARCs: Clearfil SA Cement Automix (SA; Kuraray Noritake Dental), RelyX Unicem 2 Automix (UC; 3 M ESPE) and BeautiCem SA (BC; Shofu), were used. Bovine dentin was wet-ground with #600 SiC paper. Resin columns (4 mm in diameter, 2 mm in height) were cemented and light-irradiated with the power density of 600 mW/cm^2 or not irradiated (chemical-cured). The shear bond strengths of 10 specimens per group were measured at a crosshead speed of 1.0 mm/min after 10 min, 1, 6, 12, and 24 h storage in a chamber at 37±1℃, 90±5 RH%. Statistical analysis was done to test for the presence of a significant difference between the mean bond strength at each test time at a significance level of 0.05. The time at which there was a significant increase in bond strength was identified as "time of increase in bond strength". Results: The dentin bond strength increased with prolonged specimen storage time. When the specimens were light-irradiated, higher bond strengths were obtained compared to those specimens without irradiation. The fracture mode of the UC specimens without irradiation changed from adhesive failure to mixed failure after 24 h storage. When the specimens were light irradiated, cohesive failure in the resin was observed for UC, and cohesive failure in the cement was observed for BC. Conclusion: The results of this study indicated that the chronological change in the dentin bond strengths of the SARCs was affected by the light irradiation of the specimen. Light irradiation with a sufficient power density is necessary to achieve optimal dentin bond strength, even in materials with a dual-cured setting reaction.