Development of Mercury Free Lamp Using External Electrode (DHEL)
-
- muguruma yusuke
- Ehime University
-
- matsuda atuya
- Ehime University
-
- takubo syuji
- Toshiba Harison Lighting
-
- motomura hideki
- Ehime University
-
- jinno masafumi
- Ehime University
Bibliographic Information
- Other Title
-
- 両側外部電極型無水銀光源(DHEL)の開発
Description
Recently as interests in environmental issues increase, demands for mercury-free fluorescent lamps are increasing because mercury is harmful to human being and environment. We are deveroping mercury-free fluorescent lamps using double helical electrode (DHEL).In this paper characteristics of rare gas discharge DHEL such as luminance, lamp current and lump power are investigated. When the ratio Xe : Ne was fixed at 7:3, total pressure at 1.33 kPa and external electrode pich 10 mm, luminance over 10000 cd/m2was established.As the future work, the best condition for the luminescence of DHEL is examined.
Journal
-
- Proceedings of Annual Conference of The Illuminating Engineering Institute of Japan
-
Proceedings of Annual Conference of The Illuminating Engineering Institute of Japan 38 (0), 138-138, 2005