THE EXPERIMENTAL STUDY ON ROOF MONITOR (2)
-
- KATSUTA CHITOSHI
- Tokyo Inst. of Tech.
-
- SEKINE TAKESHI
- 東京工業大学
Bibliographic Information
- Other Title
-
- 屋根モニタによる換気に関する実験的研究 : 特に群をなす建築物の棟位置に設置した屋根モニタの換気特性について
- ヤネ モニタ ニ ヨル カンキ ニ カンスル ジッケンテキ ケンキュウ トクニ グン オ ナス ケンチクブツ ノ ムネ イチ ニ セッチ シタ ヤネ モニタ ノ カンキ トクセイ ニ ツイテ
Search this article
Abstract
1. In order to calculate natural ventilation of roof monitor equied with the block of factorys which is caused by wind, we made wind tunnel experiment using the model of the block of 5 factorys which have J type roof monitor (see fig. 2), and obtained its ventilating property in natural wind. 2. Calculation of ventilating volume of roof monitor is followed the same equation in report 1. 3. This experimental study is made using about 1/400 model of factory, and indicated monitors value of pressure loss coefficent ζ_<m0*gt; and wind pressure coefficient C_<m0> when wind direction θ changed. These result is indicated Fig. 5〜8.
Journal
-
- Transactions of the Architectural Institute of Japan
-
Transactions of the Architectural Institute of Japan 104 (0), 21-25, 1964
Architectural Institute of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680546662272
-
- NII Article ID
- 110006158174
-
- NII Book ID
- AN0018882X
-
- ISSN
- 24330027
- 03871185
-
- NDL BIB ID
- 9155764
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed