VERIFICATION ON EFFECTIVENESS OF A TUNED VISCOUS MASS DAMPER AND ITS APPLICABILITY TO NON-LINEAR STRUCTURAL SYSTEMS
-
- ARAI Tatsuro
- Graduate Student, Dept. of Architecture and Building Science, Graduate School of Eng., Tohoku University
-
- ABURAKAWA Tatsuki
- Formar Graduate Student, Dept. of Architecture and Building Science, Graduate School of Eng., Tohoku University
-
- IKAGO Kohju
- Assoc. Prof., Dept. of Architecture and Building Science, Graduate School of Eng., Tohoku University, Dr. Eng.
-
- HORI Norio
- Assoc. Prof., Dept. of Architecture, Tohoku Institute of Technology, Dr. Eng.
-
- INOUE Norio
- Prof., Dept. of Architecture and Building Science, Graduate School of Eng., Tohoku University, Dr. Eng.
Bibliographic Information
- Other Title
-
- 同調粘性マスダンパーの有効性の検証と弾塑性構造物への適用性
Description
In this paper, comparison is made between vibration control systems using viscous damper, viscous mass damper and tuned viscous mass damper. It is shown that the vibration control system using the viscous mass damper is the most effective for linear structural system with the dampers having same damping ratio. Effectiveness of the present vibration control system is verified conducting shaking table tests with small scaled tuned viscous mass dampers.<br> And, applicability of the present vibration control system to non-linear structural systems subjected to seismic ground motions is also shown by performing non-linear time history analyses.
Journal
-
- Journal of Structural and Construction Engineering (Transactions of AIJ)
-
Journal of Structural and Construction Engineering (Transactions of AIJ) 74 (645), 1993-2002, 2009
Architectural Institute of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680580370304
-
- NII Article ID
- 130004507705
-
- ISSN
- 18818153
- 13404202
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed