DYNAMIC TEST ON PARTIALLY REINFORCED CONVENTIONAL CEILINGS AND SIMULATION ANALYSES
-
- HANZAWA Tetsuya
- Institute of Technology, Shimizu Corporation, M. Eng.
-
- TANAKA Eiji
- Institute of Technology, Shimizu Corporation, M. Eng.
-
- SUZUKI Kenji
- Institute of Technology, Shimizu Corporation, M. Eng.
-
- SAKURABA Fumihiko
- Institute of Technology, Shimizu Corporation, M. Eng.
-
- KANEKO Mika
- Institute of Technology, Shimizu Corporation, Dr. Eng.
Bibliographic Information
- Other Title
-
- 部分補強された在来工法天井の動的加振実験とシミュレーション解析
- ブブン ホキョウ サレタ ザイライ コウホウ テンジョウ ノ ドウテキカシンジッケン ト シミュレーション カイセキ
Search this article
Abstract
In recent years, the collapse of ceilings due to earthquakes has become a serious problem. The authors have proposed the reinforcing method to improve the aseismic performance of conventional ceilings. The proposed method employs the partial reinforcement only around the braces of ceilings, and can be easily and economically applied. The shaking table tests of the partially reinforced ceilings were carried out to investigate dynamic characteristics. The analytical model of the reinforced ceilings is proposed based on the static cyclic loading tests and the simulation analyses were carried out to show the effectiveness of the analytical model.
Journal
-
- Journal of Structural and Construction Engineering (Transactions of AIJ)
-
Journal of Structural and Construction Engineering (Transactions of AIJ) 80 (707), 167-175, 2015
Architectural Institute of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680580568448
-
- NII Article ID
- 130005060760
-
- NII Book ID
- AN10438559
-
- ISSN
- 18818153
- 13404202
-
- NDL BIB ID
- 026023244
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed