A new furnace for high-resolution synchrotron powder diffraction measurements

Bibliographic Information

Other Title
  • 高分解能放射光粉末回折測定用加熱装置の開発

Description

We have designed and fabricated a new furnace for high-resolution synchrotron powder-diffraction measurements at high temperatures up to 1600°C. Here we report that the present furnace is very powerful to study the crystal structure and the charge density distribution of ceramic materials at high temperatures up to 1600°C. This paper reports the following experimental results. (1) The present high-resolution technique enables to split the I4/mcm 004 and 220 peaks. (2) The intermediate Cmcm phase does not exist. (3) The covalency at Ti-O bonding for I4/mcm phase is smaller than that for Pbnm form. (4) I4/mcm structure has isotropic charge density distribution comparing with Pbnm structure.

Journal

Details 詳細情報について

  • CRID
    1390282680590859648
  • NII Article ID
    130006970233
  • DOI
    10.14853/pcersj.2002f.0.236.0
  • Data Source
    • JaLC
    • CiNii Articles
  • Abstract License Flag
    Disallowed

Report a problem