EVALUATION OF UNI-AXIAL TENSILE MODEL FOR HIGH PERFORMANCE FIBER REINFORCED CEMENTITIOUS COMPOSITES : Part 1 Experimental evaluation method for first crack strength and strain

Bibliographic Information

Other Title
  • 高靭性セメント系複合材料の一軸引張モデル評価法 : その1 初期ひび割れ点の簡易実験評価法
  • 高靱性セメント系複合材料の一軸引張モデル評価法(その1)初期ひび割れ点の簡易実験評価法
  • コウジンセイ セメントケイ フクゴウ ザイリョウ ノ 1ジク ヒッパリ モデル ヒョウカホウ ソノ 1 ショキ ヒビワレ テン ノ カンイ ジッケン ヒョウカホウ

Search this article

Description

High performance fiber reinforced cementitious composites (HPFRCC) have, tensile capacity of several percent strain. The objective of this study is mainly to evaluate uni-axial tensile model of HPFRCC for design procedure utilization and certification on construction site. In this paper, experimental evaluation method for first crack strength and strain is proposed using results of splitting and compression test of cylinder test pieces. The first crack strength obtained by splitting test shows a good agreement with that obtained by uni-axial tensile test using hourglass test piece. Elastic modulus obtained by compression test has a good relationship with that of uni-axial tensile test. As a result, crack strength and strain can be evaluated by the simple experimental tests.

Journal

Citations (2)*help

See more

References(10)*help

See more

Details 詳細情報について

Report a problem

Back to top