すべり破壊を生ずるSRC構造非埋込み形柱脚のせん断挙動と終局耐力

書誌事項

タイトル別名
  • ULTIMATE STRENGTH OF UNEMBEDDED TYPE COLUMN BASES IN SRC STRUCTURES UNDER SHEAR SLIP FAILURE
  • すべり破壊を生ずるSRC構造非理込み形柱脚のせん断挙動と終局耐力
  • スベリ ハカイ オ ショウズル SRC コウゾウ ヒウメコミガタ チュウキャク ノ センダン キョドウ ト シュウキョク タイリョク

この論文をさがす

抄録

The shear slip failure of unenbedded type column bases in SRC structures were reported by Hyogoken-Nanbu earthquake and the experimental research in recent years. However, there has been no study that tried to evaluate ultimate shear strength of unenbedded type column bases. We describe the structual test carried out in order to study ultimate shear strength and hysteresis property of unenbedded type column bases. Structural test made it clear that mechanical property depends on the axial force level, and the anchor bolts is not valid for ultimate shear strength. We proposed the evaluation method of ultimate shear strength. Ultimate shear strength of column base is calculate by applying the superposed strength method, in which the ultimate shear strength of the anchor bolts and friction between the base plate and the concrete below the base plate is taken to be the sum of the punching shear strength of the RC portion surrounding the base plate. Proposed evaluation method of untimate shear strength is in accordance with the test result well.

収録刊行物

参考文献 (11)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ