木質ラーメン構造による実大3層立体フレームの振動台実験

書誌事項

タイトル別名
  • SHAKING TABLE TEST OF FULL SCALE 3-STORY TIMBER FRAME
  • モクシツ ラーメン コウゾウ ニ ヨル ジツダイ 3ソウ リッタイ フレーム ノ シンドウダイ ジッケン

この論文をさがす

抄録

Full-scale tests were carried out to examine the seismic performance of three-story timber frame structure with moment resisting joints. Size of this frame is 5,460mm by 5,460mm wide and 8,580mm height, total weight was 163kN. Specification of damage points, i.e. repair point, was controllable with this method which is concentrated damage points to the joint parts. This structural frame was repaired after the shaking table tests, and examined the effect of these repairs. The experimental result showed not only high resistance to earthquake but also effect of repairs. About comparison of experiments and analysis, both Static and Dynamic analysis almost coincided with each experimental results.