Prevention of cross infection with ultrasonic diagnostic equipment
-
- OGAWA Ayano
- Department of Medical Laboratory, Tokai University Hospital
-
- GOTO Reiko
- Department of Medical Laboratory, Tokai University Hospital
-
- KOYANAGI Noriko
- Department of Medical Laboratory, Tokai University Hospital
-
- TAKAHASHI Akiko
- Department of Medical Laboratory, Tokai University Hospital
-
- TAKANASHI Noboru
- Department of Medical Laboratory, Tokai University Hospital
-
- ASAI Satomi
- Department of Laboratory Medicine, Tokai University School of Medicine
-
- MIYACHI Hayato
- Department of Laboratory Medicine, Tokai University School of Medicine
Bibliographic Information
- Other Title
-
- 超音波診断装置による交差感染防止対策
Search this article
Description
In performing a physiological examination of diseased patients, precautions against an indirect-contact-route transmission of infections are critical to ensuring patient safety. We studied the causes of noncompliance to cleaning and disinfection of the surfaces of ultrasonic diagnostic equipment and its accessories after examination of each patient and developed effective measures to improve compliance according to the study results. Fluorescent dye paste in combination with a black light for the study of hand hygiene compliance was used for identifying areas of insufficient cleaning and disinfection after patient examination by 11 medical technologists. As a result, the surfaces of clinical equipment, such as the track ball and operation panels, which have uneven surfaces, were found to be insufficiently cleaned. Furthermore, some staff members failed to clean the surfaces of clinical items, such as a jelly container, touch panel light, and barcode-reading sensors, and the surface of the equipment on the patient side. In summary, insufficient cleaning and disinfection of ultrasonic diagnostic equipment occurs, which is mainly attributable to a failure in the education and training systems. It is necessary to educate the examiners using feedback of the investigation results on compliance and to enhance compliance using a standard operation procedure and a checklist-based risk assessment.
Journal
-
- Japanese Journal of Medical Technology
-
Japanese Journal of Medical Technology 65 (2), 172-180, 2016
Japanese Association of Medical Technologists
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680718337280
-
- NII Article ID
- 130005151819
-
- ISSN
- 21885346
- 09158669
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed