Investigation of differential pressure rise and corrosion of GGH in flue-gas desulfurization process and their countermeasures at Nanao Ota Thermal Power Plant Unit#2
-
- Nakahashi S.
- Hokuriku Electric Power Company
Bibliographic Information
- Other Title
-
- 七尾大田火力発電所2号機 排煙脱硫装置GGHの差圧上昇および腐食原因とその対応
Description
At Nanao Ota Thermal Power Plant Unit#2, the rise in the differential pressure of the heat receiving section of GGH in flue-gas desulfurization process and a corrosion of the heat recovery section have been observed. Both were caused by the deterioration of flue-gas NOx removal catalyst. The investigation and the countermeasures taken are presented.