- MINATO Akihiko
- Hitachi, Ltd.
-
- KATOUNO Kenichi
- Hitachi, Ltd.
-
- NAGAHARA Takahide
- Hitachi Industries, Co., Ltd.
-
- KARIYA Kougi
- Hitachi, Ltd.
-
- NAKAJIMA Nobuyuki
- Hitachi, Ltd.
Bibliographic Information
- Other Title
-
- 2507 砕波による自由液面からの気泡巻込みの数値解析(OS-25B,OS-25 混相流および界面挙動の数値解析)
Abstract
The present study is a part of development studies of numerical tools for free surface flow and multi-phase flow problems in pumping stations. The numerical method is SP-VOF (Simplified Piecewise Linear Interface Calculation and Volume of Fluid). It is necessary to estimate bubble entrainment from free surface to pump site in order to design high performance pumping plants. Most bubble entrainment occurs at a junction of open and closed channels, where agitated free surface contacts with structure wall. Small-scale tests of air entrainment at a junction were calculated. The critical velocity for incipient air entrainment due to break wave was well calculated.
Journal
-
- The Proceedings of The Computational Mechanics Conference
-
The Proceedings of The Computational Mechanics Conference 2005.18 (0), 811-812, 2005
The Japan Society of Mechanical Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680833967872
-
- NII Article ID
- 110006214193
-
- ISSN
- 24242799
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed