- Sakamoto Shintaro
- The University of Electro-Communications
-
- Kaiho Kazuhiro
- The University of Electro-Communications
-
- Enoki Koji
- The University of Electro-Communications
-
- Okawa Tomio
- The University of Electro-Communications
Bibliographic Information
- Other Title
-
- 強制対流サブクール沸騰の数値解析における気泡の伝熱面離脱条件の影響
Description
<p>Numerical simulation of subcooled flow boiling in a vertical rectangular duct was carried out using a one-way bubble tracking method; this method treats each bubble as an individual particle. Although a bubble behavior after lifting off the heated surface depends on the bubble size and velocity at lift-off, these lift-off conditions are not taken into consideration in existing subcooled flow boiling models. In the present simulation, the distributions of lift-off velocity and bubble size were considered. It was demonstrated that the calculated void fraction in subcooled flow boiling is influenced significantly by the lift-off conditions.</p>
Journal
-
- The Proceedings of the Thermal Engineering Conference
-
The Proceedings of the Thermal Engineering Conference 2016 (0), C221-, 2016
The Japan Society of Mechanical Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680857466880
-
- NII Article ID
- 130007135584
-
- ISSN
- 2424290X
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed