Fukushima Daiichi NPP accident would be terminated, if sufficient accident countermeasures, such as water proof door, mobile power, etc. In case of Europe, it had already installed the heat removal system and filtered containment venting system (FCVS) from the lessons of TMI and Chernobyl Accidents. Decay heat removal system and CV spray cooling system with FCVS are ensured by using mobile generators and heat exchangers to keep the ultimate heat sink even in any natural disaster, such as large earthquake, big tsunami, sudden flooding etc. In this paper we introduce high decontamination factor FCVS that used Silver Zeolite named AgX, developed by Rasa Industries, Ltd. Hokkaido University has tested wet type FCVS using venturi scrubber in water pool and dry type FCVS using metallic fiber filter for 1st stage, and AgX for 2nd stage. Since the AgX needs super heat steam, it is possible to heat up steam by heat exchanger. It is confirmed by TRAC analysis.