C214 Visualization Test Using Piping Group Mock Up Specimen for Evaluation of Wastage Phenomena in Steam Generator for FBR
-
- KATO Keisuke
- Hokkaido University
-
- YOSHIDA Atsuro
- Hokkaido University
-
- ARAE Kunihiko
- Hokkaido University
-
- NARABAYASHI Tadashi
- Hokkaido University
-
- OHSHIMA Hiroyuki
- Japan Atomic Energy Agency
-
- KURIHARA Akikazu
- Japan Atomic Energy Agency
Bibliographic Information
- Other Title
-
- C214 高速炉SGウェステージ評価用管群可視化試験(OS8 軽水炉・新型炉・原子力安全)
Description
There is a need for quantitative evaluation of wastage phenomena in steam generator for FBR. We focused attention on liquid droplet impingement erosion (LDIE) in wastage phenomena and performed basic study with piping group mock up specimen for quantitative evaluation of LDIE. First, we did visualization test of high pressure and high speed jet into the water. Test section mock up the crack of heat exchanger tube and neighboring heat exchanger tubes. We did the test under the following test conditions. Upstream pressure is 0.3MPa, vapor temperature is 300K, crack width is 0.1mm, and crack length is 40mm. (crack diameter is 0.2mm) Second, we did pressure and temperature measurement test in the same test conditions as before. We evaluated jet behavior at test section by those two tests. In addition, we did two phase flow analysis of the jet with TRAC code.
Journal
-
- The Proceedings of the National Symposium on Power and Energy Systems
-
The Proceedings of the National Symposium on Power and Energy Systems 2012.17 (0), 317-318, 2012
The Japan Society of Mechanical Engineers
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680862749824
-
- NII Article ID
- 110009919703
-
- ISSN
- 24242950
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed