書誌事項
- タイトル別名
-
- E113 Ambient Temperature and Part-load Characteristics of the Advanced Humid Air Turbine System
説明
Ambient temperature effects and part-load characteristics of the AHAT (Advanced Humid Air Turbine) system were studied both experimentally and analytically. Firstly, these characteristics of the 3MW AHAT pilot plant were measured and they were compared with heat and material balance calculation results. Secondly, these characteristics of the AHAT and the combined cycle were calculated assuming they were composed of mid-sized industrial gas turbines which have axial flow compressors and axial flow turbines. As for the part-load characteristics, when the IGV (Inlet Guide Vane) were operated so as to keep the turbine exhaust temperature at a constant value, degradation of electrical efficiency of the AHAT was smaller than that of the combined cycle.
収録刊行物
-
- 動力・エネルギー技術の最前線講演論文集 : シンポジウム
-
動力・エネルギー技術の最前線講演論文集 : シンポジウム 2010.15 (0), 199-202, 2010
一般社団法人 日本機械学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680862810368
-
- NII論文ID
- 110008739956
-
- ISSN
- 24242950
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可