- 中尾 雄一
- OVAL Corporation Yokohama Operations Center
書誌事項
- タイトル別名
-
- 235 Coriolis Mass Flowmeter for Flow Measurement of High Pressure Hydrogen
抄録
In order to prepare for the sales expansion of FCV (fuel-cell vehicle) around the comer, hydrogen stations are steadily increasing. We released a most suitably designed Coriolis flowmeter for hydrogen dispensers in 2005. Since then, the models have been adopted in many hydrogen stations of pressure levels, 35MPa and 70MPa and accumulating its quantity delivered for flow measurement, as well as contributing to R&D by relevant FCV makers. In a verification test by JHFC (Japan Hydrogen & Fuel Cell Demonstration Project) , the flowmeter achieved the target for 70MPa hydrogen dispensers of filling in a FCV's 5kg tank in 3 min. by improving the filling time and efficiency to the better. Further, safety functions have constantly been under consideration, resulting in to change the measuring tube material from Alloy C to SUSS 10S, which does not embrittle even when exposed to high pressure hydrogen gas. In this thesis, technical features of the flowmeter and results of the filling tests are introduced, and the improvement process up to now and future prospects are reported.
収録刊行物
-
- Dynamics & Design Conference
-
Dynamics & Design Conference 2011 (0), _235-1_-_235-10_, 2011
一般社団法人 日本機械学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680864964992
-
- NII論文ID
- 110009690984
-
- ISSN
- 24242993
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可