Experiments on the Pressure Drop, Flow Rate and Flow Ratio in Hydrocyclones with similar figures
-
- FUJIMOTO Toshiharu
- 工業技術院資源技術試験所第5部第3課
-
- MORO Tadao
- 工業技術院資源技術試験所第5部第3課
Bibliographic Information
- Other Title
-
- 相似形サイクロンによる圧力損失, 流量および流量比の研究
- ソウジケイ サイクロン ニ ヨル アツリョク ソンシツ , リュウリョウ オヨビ リュウリョウヒ ノ ケンキュウ
Search this article
Abstract
The authors have measured the pressure difference between the inlet and the overflow pipe, and the flow rate, i. e. the feed rate under various operating conditions.<BR>In addition to the above results, the authors have shown the following three experimental formulae:(1) The pressure drop through the hydrocyclone may be represented by the formula (3·6), (2) Flow rate may be expressed as equation (3·14) and (3) Flow ratio as the overflow rate divided by the feed rate may be expressed as equation (3·15).
Journal
-
- Journal of the Mining and Metallurgical Institute of Japan
-
Journal of the Mining and Metallurgical Institute of Japan 79 (901), 491-497, 1963
The Mining and Materials Processing Institute of Japan