書誌事項
- タイトル別名
-
- Numerical Simulation of Pulsatile Flow around Stent Used for Treatment of Aneurysms. In the Case of Tori-Modeled Stent.
- ドウミャクリュウチリョウヨウ ノ ステント マワリ ノ ハクドウリュウ ニ カンスル スウチ シミュレーション トーラスレツ モデル ノ ステント ノ バアイ
この論文をさがす
説明
Three-dimensional numerical simulation is performed of pulsatile flow around a tori-modeled stent inserted into parent artery below a neck of sidewall aneurysm. When blood flow in the aneurysm is suppressed by the stent, thrombus is generated in the aneurysm resulting in prevention of development and rupture of the aneurysm. The mechanism is clarified which the flow is induced in the aneurysm even when the aneurysm neck is covered by fluid-dynamic obstacles of stent filaments. The averaged maximum Reynolds number is chosen as 250 and Womersley number as 2.7. It is shown that flow-inducing sources are pressure difference between proximal and distal sides in the aneurysm neck and kinetic energy flowing into the aneurysm at the proximal side whose direction is turned from axial to radial directions and whose magnitude is reduced due to impingement of boundary-layer flow in the parent artery. Possibility of the thrombus formation on the aneurysm wall is evaluated using the shear rate.
収録刊行物
-
- 日本機械学会論文集B編
-
日本機械学会論文集B編 68 (676), 3288-3294, 2002
一般社団法人 日本機械学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282681159366400
-
- NII論文ID
- 130004080629
- 110002387697
-
- NII書誌ID
- AN00187441
-
- ISSN
- 18848346
- 03875016
-
- NDL書誌ID
- 6421196
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDLサーチ
- Crossref
- CiNii Articles
- KAKEN
-
- 抄録ライセンスフラグ
- 使用不可