Heat Transfer in Pool Boiling of Ammonia-Water Mixture.

Bibliographic Information

Other Title
  • アンモニア‐水二成分系プール沸騰熱伝達
  • アンモニア ミズ 2セイブンケイ プール フットウ ネツ デンタツ

Search this article

Abstract

The nonazeotropic binary mixtures such as, methanol-water, ethanol-water and ammonia-water, have variable boiling and dew points, depending on the mixture components and those concentrations. It is expected to have a higher coefficient of performance as a result of decreasing the thermodynamically irreversible loss, when there is a relevant concentration. Therefore, ammonia-water mixture is used as working fluid in small temperature difference power generation cycles and absorption refrigeration cycles. However, few experiments were carried out for measuring heat transfer coefficient for ammonia-water mixture in the world. Therefore, an experimental study has been carried out to measure boiling heat transfer coefficient of an ammonia-water mixture on a horizontal heated surface at low pressure of 0.2, 0.4 and 0.7MPa and at low concentration of 0<C<0.5 and at high pressure 0.7, 1.0, 1.5MPa and at concentration of 0.5<C<1.0 and at heat flux under critical heat flux the heat trasfer coefficient are compared with existing correlations prediction and a revised correlation can be proposed to predict them well.