Ultrathin (5 µm) Flexible Reflective Waveplate of Fluorinated Polyimide and Elimination of Polarization Sensitivity in Titanium-Diffused Lithium Niobate Waveguide Circuits

  • Sawada Takashi
    NTT Science and Core Laboratory Group, 3–9–11, Midori–cho, Musashino, Tokyo 180–8585, Japan
  • Ando Shinji
    NTT Science and Core Laboratory Group, 3–9–11, Midori–cho, Musashino, Tokyo 180–8585, Japan
  • Miyazawa Hiroshi
    NTT Opt–electronics Laboratories, 3–1, Morinosato Wakamiya, Atsugi, Kanagawa 243–0198, Japan
  • Takenaka Hisataka
    NTT Science and Core Laboratory Group, 3–9–11, Midori–cho, Musashino, Tokyo 180–8585, Japan
  • Sasaki Shigekuni
    NTT Science and Core Laboratory Group, 3–9–11, Midori–cho, Musashino, Tokyo 180–8585, Japan

書誌事項

タイトル別名
  • Ultrathin (5.MU.m) Flexible Reflective Waveplate of Fluorinated Polyimide and Elimination of Polarization Sensitivity in Titanium-Diffused Lithium Niobate Waveguide Circuits.

抄録

An ultrathin, flexible reflective half-waveplate, consisting of a 5-µm-thick polyimide quarter-waveplate sputtered with a thin gold film, was fabricated, and its property of eliminating polarization sensitivity in titanium-diffused lithium niobate waveguide circuits was investigated. Transverse electric/transverse magnetic mode-conversion ratios of 15-20 dB at 1.55 µm were obtained, and a polarization-insensitive intensity modulator with a low half-wave voltage of 4.5 V was successfully fabricated using a titanium-diffused lithium niobate waveguide. The excess loss of the polyimide reflective waveplate (1 dB) was much smaller than that using a conventional quartz waveplate (6 dB).

収録刊行物

被引用文献 (2)*注記

もっと見る

参考文献 (15)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘