Convenient Potentiostatic Polarization with Two Electrode System
-
- Tsuru Tooru
- Tokyo Institute of Technology
-
- Itagaki Masayuki
- Tokyo Institute of Technology
-
- Hashimoto Kouji
- Tokyo Institute of Technology Present adness: Nippon Steel Corporation
-
- Nishikata Atsushi
- Tokyo Institute of Technology
Bibliographic Information
- Other Title
-
- 二電極法による簡便な定電位分極
- 2電極法による簡便な定電位分極
- 2 デンキョクホウ ニ ヨル カンベン ナ テイ デンイ ブンキョク
Search this article
Description
Two electrode system, in which the Ag/AgCl electrode serving both as a reference and a counter electrode, has been applied to the potentiostatic polarization in an aqueous solution containing chloride ions. It is experimentally very convenient and useful method in the potentiostatic polarization with small current, such as the cathodic polarization of coated steel for accelerated test of film delamination and the pitting incubation period measurement of stainless steel.
Journal
-
- CORROSION ENGINEERING
-
CORROSION ENGINEERING 37 (6), 361-364, 1988
Japan Society of Corrosion Engineering
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282681235191808
-
- NII Article ID
- 130006025305
- 130004732039
-
- NII Book ID
- AN00225595
-
- ISSN
- 18841155
- 00109355
-
- NDL BIB ID
- 3182485
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed