A New Portable Instant-off Potentiometer for Inspecting Cathodic Protection of Steel Rebars in Concrete
-
- Kodama Toshiaki
- R&D Laboratories, Nakabohtec Corrosion Protecting Co. Ltd.
-
- Shinoda Yoshio
- RC Development Divison, Nakabohtec Corrosion Protecting Co. Ltd.
-
- Tanaka Kazuhiro
- RC Development Divison, Nakabohtec Corrosion Protecting Co. Ltd.
Bibliographic Information
- Other Title
-
- 鉄筋の電気防食の検査用携帯型インスタントオフ電位計の開発
- テッキン ノ デンキ ボウショク ノ ケンサヨウ ケイタイガタ インスタントオフ デンイケイ ノ カイハツ
Search this article
Description
In cathodic protection (CP) by impressed current method, polarization decay, a shift in potential following the switch-off of CP current, is used as parameter of adequate operation especially in the media of high resistivity, where iR-drop compensation is indispensable. Instant-off potential, sampled immediately after switch-off of CP current, is an essential parameter that represents effective ON-potential (with iR-drop compensation) and a baseline for the polarization decay. A detailed analysis of potential transient demonstrated that a transition from iR-drop to electrochemical relaxation starts within a millisecond in concrete. A novel portable instant-off potentiometer that allows direct reading of the instant-off potential was developed. The potentiometer consists of (a) generation of timing pulses for driving MOS switches and triggering an AD converter, (b) switching of CP current with variable ON/OFF interval and duty ratio, and (c) fast AD conversion triggered synchronously with ON/OFF timing followed by storing and computing the average. Noise level was minimized by properly selecting the sampling interval and by synchronizing the logging timing with the power-line wave but dispersing phase shifts of sampling points. A typical example of data logging interval and timing, duty cycle, and sampling number for averaging is shown for minimizing noise level of power-line origin. The potentiometer allowed direct display of the instant-off potential with the interval of 1.6 s. The measurements by model concrete block and concrete bridge on-site have proven the effectiveness and validity of the potentiometer.
Journal
-
- Corrosion Engineering
-
Corrosion Engineering 59 (5), 187-194, 2010
Japan Society of Corrosion Engineering
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282681235197824
-
- NII Article ID
- 10026347505
-
- NII Book ID
- AN10235427
-
- ISSN
- 18819664
- 09170480
-
- NDL BIB ID
- 10709908
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed