Corrosion in The Electrical or Electronic Components of Telecommunications Equipment

  • Handa Takao
    Technical Assistance and Support Center, Nippon Telegraph and Telephone East Corporation
  • Miyata Yoshimori
    Technical Assistance and Support Center, Nippon Telegraph and Telephone East Corporation

Bibliographic Information

Other Title
  • 通信装置類における電気・電子部品の腐食事例
  • 解説 通信装置類における電気・電子部品の腐食事例
  • カイセツ ツウシン ソウチルイ ニ オケル デンキ デンシ ブヒン ノ フショク ジレイ

Search this article

Description

The provision of economical telecommunications service requires effective maintenance management of a huge infrastructure of telecommunications equipment. A major maintenance concern is corrosion of the many metal components in telecommunications equipment. This paper examines the corrosion of the electrical or electronic components in telecommunications equipment, for example, corrosion in past conventional telephone switching equipment such as cross-bar switches that use mechanical contacts, the electrolytic corrosion in telephone jacks, and the sulfurization corrosion of Ag line patterns on semiconductor substrates. In addition, we examine the problem of corrosion in the closed packages of outdoor equipment caused by an accumulation of sea salt particles, dust, and humidity in the future.

Journal

  • Zairyo-to-Kankyo

    Zairyo-to-Kankyo 49 (11), 649-654, 2000

    Japan Society of Corrosion Engineering

Citations (9)*help

See more

References(5)*help

See more

Details 詳細情報について

Report a problem