Application of a rapid scanning spectrometer to study on behaviors of Mn atoms and ions in an Ar-He capacitively coupled microwave plasma.
書誌事項
- タイトル別名
-
- Application of a Rapid Scanning Spectro
この論文をさがす
抄録
A rapid scanning spectrometer with a rotating grating which was directly driven by a synchronous motor was applied to a study on behaviors of Mn atoms and ions in an Ar-He capacitively coupled microwave plasma used for atomic emission spectrometry. A wave length range from 200 to 800 nm (the first order) were scanned within 0.2 sec during a rotation of the grating (30 rpm). Two atomic emission lines and two ionic ones of Mn were observed to estimate excitation temperatures, degree of ionization and total number of atoms and ions. These parameters notably changed in magnitude with plasma gas composition and concentration of Li or Na as a matrix.
収録刊行物
-
- 分光研究
-
分光研究 38 (6), 425-431, 1989
社団法人 日本分光学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282681236387456
-
- NII論文ID
- 130000948959
-
- NII書誌ID
- AN00222531
-
- ISSN
- 18846785
- 00387002
-
- NDL書誌ID
- 3653619
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可