Measuring Condition and Precision of Vibration Intensity Measurement in Plates.

Bibliographic Information

Other Title
  • 二次元振動インテンシティ計測における計測条件と計測誤差
  • 2ジゲン シンドウ インテンシティ ケイソク ニ オケル ケイソク ジョウケン

Search this article

Abstract

Errors involved in bending vibration intensity measurement consist of systematical errors due to finite difference and random errors. Both errors are investigated through analysis and experimentation. A correction factor is proposed to minimize the errors due to the finite difference for the general measuring condition. The following results are obtained. ( 1 ) The method which uses 9 measuring points is recommended for measuring the intensity in a far-field condition. ( 2 ) The condition to minimize the random errors is proposed; the product of wave number k and the space Δ between sensors is specified in the paper. ( 3 ) The method which uses 4 measuring points gives a larger value than the actual one.

Journal

Citations (3)*help

See more

Details 詳細情報について

Report a problem

Back to top