原子力発電所電算機システムのCRTディスプレイ装置の耐震性の実験的評価

書誌事項

タイトル別名
  • Experimental Seismic Evaluation for CRT Displays of Process Computer Systems in Nuclear Power Plants.
  • ゲンシリョク ハツデンショ デンサンキ システム ノ CRT ディスプレイ ソ

この論文をさがす

説明

Fault-tree analysis was carried out to evaluate whether CRT displays are capable of maintaining display functions during earthquakes. When considering the possible failure modes, it is necessary to pay particular attention to the vibration of the internal components, such as the shadow mask and electron gun assembly. The natural frequencies and the seismic responses of these components were analyzed to evaluate whether or not the functional capabilities of CRT displays are affected. The CRT display vibration tests were performed using a shaking table, and the functional capabilities of the CRT display during simulated design earthquakes were verified.