産業用X線トモグラフィ装置による材料欠陥およびミクロ組織の3D可視化

書誌事項

タイトル別名
  • 3D visualization of defects and microstructural features with laboratory-scale X-ray tomography apparatuses
  • 結晶粒の塑性変形挙動の3D/4D追跡技術
  • ケッショウリュウ ノ ソセイ ヘンケイ キョドウ ノ 3D/4D ツイセキ ギジュツ
  • サンギョウヨウ Xセン トモグラフィ ソウチ ニ ヨル ザイリョウ ケッカン オヨビ ミクロ ソシキ ノ 3D カシカ
  • 3D/4D Tracking Technique for Investigation of Grain Deformation Behavior

この論文をさがす

抄録

In the present study, various microstructural features, such as particles and pores, have been visualized in cast and wrought aluminum alloys by employing X-ray tomography apparatuses with a wide range of spatial resolution. Special care is dedicated to evaluate an identical sample for each entire series of imaging experiments. The X-ray tomography apparatuses used include the one performed at a synchrotron radiation facility, which has a spatial resolution level close to the theoretical limit of the projection-type imaging, in addition to two industrial apparatuses. It has been shown that even if industrial apparatuses, which inevitably possess limited spatial resolution levels, are used, the real size and fraction of microstructural features can be estimated by performing imaging experiments above a certain spatial resolution level. It would be, so far as the authors are aware, the first time to demonstrate the feasibility of laboratory-scale X-ray tomography imaging in microstructural observation in a systematic manner, especially focusing on spatial resolution and quantitative capability.

収録刊行物

  • 軽金属

    軽金属 63 (10), 343-349, 2013

    一般社団法人 軽金属学会

被引用文献 (1)*注記

もっと見る

参考文献 (78)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘