Study on Patch Test Reagent for Titanium
-
- NAKAJIMA Koki
- Fixed Prosthodontics, Department of Restorative Sciences, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University
Bibliographic Information
- Other Title
-
- チタンに対するパッチテスト試薬の検討
- チタン ニ タイスル パッチ テスト シヤク ノ ケントウ
Search this article
Abstract
Recently, allergy to titanium has been reported. However, the patch test reagent for titanium is not standardized yet. The form and density of the patch test reagent for titanium was changed and examined in a group of normal subjects and a group with skin disease. The following conclusions were obtained.<BR>1. A reagent which was composed of pure titanium powder and vaseline was not preferable because its form was a stimulant.<BR>2. If the form of the titanium powder was not sharp even though it was not spherical, it did not cause a stimulated reaction.<BR>3. It is suggested that TiCl4 0.1% is preferable as a patch test reagent for titanium.
Journal
-
- THE JOURNAL OF THE STOMATOLOGICAL SOCIETY,JAPAN
-
THE JOURNAL OF THE STOMATOLOGICAL SOCIETY,JAPAN 74 (2), 92-98, 2007
The Stomatological society, Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282681319803392
-
- NII Article ID
- 130004283070
- 40015556306
-
- NII Book ID
- AN00302674
-
- ISSN
- 18845185
- 03009149
-
- NDL BIB ID
- 8880315
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed