Sound Insulation of Wooden Three-layered Material II. Floor-impact sound level of wooden three-layered floors
-
- Nakamura Tetsuo
- Graduate School of Science and Technology, Kumamoto University
-
- Yano Takashi
- Graduate School of Science and Technology, Kumamoto University
-
- Murakami Kiyoshi
- Graduate School of Science and Technology, Kumamoto University
-
- Hasegawa Asako
- Graduate School of Science and Technology, Kumamoto University
-
- Etoh Tomehisa
- Shinko Co Ltd.
-
- Takahashi Yuki
- Shinko Co Ltd.
-
- Kitahara Ryosei
- Forest Co Ltd.
Bibliographic Information
- Other Title
-
- 木質3層構造材の遮音性能(第2報) 3層床の床衝撃音レベル
- モクシツ 3ソウ コウゾウザイ ノ シャオン セイノウ ダイ2ホウ 3ソウショウ ノ ユカショウゲキオン レベル
- Sound Insulation of Wooden Three-layered Material II.
- Floor-impact sound level of wooden three-layered floors
- 3層床の床衝撃音レベル
Search this article
Description
In the present study the floor impact sound insulations of three-layered floors composed of cedar timber and plywood was measured and evaluated in accordance with JIS A 1418-1, JIS A 1418-2, and JIS A 1419-2, and compared with that of conventionally constructed floors. The results were summarized as follows : (1) The light and heavy floor impact sound insulations of the three-layered floors was better than that of conventionally constructed floor ; (2) The light floor impact sound insulation of the three-layered floors with rubber supporting the upper air layer was much better than of the others ; (3) When the joist interval is changed from 433.5 mm to 289 mm, the heavy floor impact sound insulation was improved by the increase of the stiffness ; (4) When the CFRP plate was bonded to the floor with the joist interval of 433.5 mm, the heavy floor impact sound insulation was improved. However, the CFRP plate had no effect in the case of the floor with the joist interval of 289 mm, because bonding the CFRP plate to the wooden floor was not enough to increase the stiffness.
Journal
-
- Mokuzai Gakkaishi
-
Mokuzai Gakkaishi 56 (2), 93-103, 2010
The Japan Wood Research Society
- Tweet
Details 詳細情報について
-
- CRID
- 1390282681327571456
-
- NII Article ID
- 10029788757
-
- NII Book ID
- AN00240329
-
- ISSN
- 18807577
- 00214795
-
- NDL BIB ID
- 10632673
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed