Examination of Some Factors Affected Right-to-left Shunt Rate and the Normal Value of Right-to-left Shunt Rate in Lung Perfusion Scintigraphy
-
- Nakamura Fumitoshi
- Department of Radiological Technology, Hamamatsu Medical Center
-
- Okabe Masafumi
- Department of Radiological Technology, Hamamatsu Medical Center
-
- Ono Takaaki
- Department of Radiological Technology, Hamamatsu Medical Center Current address: Department of Radiological Technology, Toyohashi Municipal Hospital
-
- Sugimura Yousuke
- Department of Radiological Technology, Hamamatsu Medical Center
-
- Muromoto Naoko
- Department of Radiological Technology, Hamamatsu Medical Center
-
- Suzuki Ryou
- Department of Radiological Technology, Hamamatsu Medical Center
-
- Okawada Taketoshi
- Department of Radiology, Hamamatsu Medical Center
Bibliographic Information
- Other Title
-
- 肺血流シンチにおける右左シャント率の変動因子と正常値の検討
- 臨床技術 肺血流シンチにおける右左シャント率の変動因子と正常値の検討
- リンショウ ギジュツ ハイ ケツリュウ シンチ ニ オケル ミギヒダリ シャントリツ ノ ヘンドウ インシ ト セイジョウチ ノ ケントウ
Search this article
Description
<p>Purpose: Diagnosis for right-to-left shunt was determined by the assessment of shunt-rate, which was obtained by using 99 mTc-macroaggregated albumin. However, it is difficult to diagnose right-to-left shunt, using the normal level of shunt-rate measured by using conventional methods. To solve this problem, we investigated ourselves the normal level of shunt-rate. Method: We researched 20 patients with pulmonary embolism, and they didn’t have right-to-left shunt. We investigated three points for the normal level of shunt-rate. First, we examined the region of interest (ROI) area of the lungs to modify the upper level of gray scale. Second, we confirmed the difference between the whole visual field and body contour of the ROI area. Third, we examined the necessity whether we correct the background of whole body and the lungs. Result: We resulted three points. First, stable right-to-left shunt rate is got to set that the upper level of gray scale is 35%. Second, there is no significant difference between the whole visual field and body contour of the ROI area. Third, correcting background isn’t needed to get right-to-left shunt rate. The normal level of the shunt-rate was 12.6±2.8% in the condition. Conclusion: We are able to decide the optimal condition for the normal level of shunt-rate. It is important to evaluate the normal level of the shunt-rate fixed on each factor in each hospital.</p>
Journal
-
- Japanese Journal of Radiological Technology
-
Japanese Journal of Radiological Technology 73 (2), 120-127, 2017
Japanese Society of Radiological Technology
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282681338030592
-
- NII Article ID
- 130005240944
-
- NII Book ID
- AN00197784
-
- ISSN
- 18814883
- 03694305
-
- NDL BIB ID
- 028017033
-
- PubMed
- 28216520
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- PubMed
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed