Colorimetric Determination of COD(Mn)Using Hydrogen Peroxide.

Bibliographic Information

Other Title
  • 過酸化水素を介してのCOD (Mn)比色法
  • 過酸化水素を介してのCOD(Mn)比色法〔英文〕
  • カサンカ スイソ オ カイシテ ノ COD Mn ヒショクホウ エイブン

Search this article

Description

Iodometric colorimetry is applied for measuring COD(Mn), using hydrogen peroxide as the mediator. It saves time, space, and chemicals without degradation of accuracy. The method can be applied to any digestion method which uses permanganate. The remaining permanganate is reduced by hydrogen peroxide at pH 1-2, where the peroxide is stable. If the silver ion for masking halides remains in the digested mixture, it is made to settle on the reduction by an excess of sodium chloride. The supernatant of digested mixture is transferred to 0.3M KI in the acetate buffer (pH 5-6) which contains molybdate (catalyst). As the peroxide oxidizes iodide within 2 min, the formed triiodide is colorimetrically measured at 353nm within 2h of reaction. Blank increase by air oxidation can be ignored during this time. The method of controlling the pH of the reaction mixture is also described.

Journal

  • NIPPON SUISAN GAKKAISHI

    NIPPON SUISAN GAKKAISHI 58 (6), 1129-1137, 1992

    The Japanese Society of Fisheries Science

Keywords

Details 詳細情報について

Report a problem

Back to top