軸対称SH波EMATによる空冷式熱交換器チューブ腐食の非破壊評価

書誌事項

タイトル別名
  • Non-destructive Evaluation of Air-Cooled Heat Exchanger Tube Corrosion by Axial Shear Resonance Using EMAT
  • ジク タイショウ SHハ EMAT ニ ヨル クウレイシキ ネツコウカンキ チューブ フショク ノ ヒハカイ ヒョウカ

この論文をさがす

抄録

In this study, an effective corrosion detection technique, using the cylindrical typed electromagnetic acoustic resonance (EMAR) wave technique, which can detected the inside corrosion of finned tubes in air-cooled heat exchangers has been developed. EMAR is a combination of the resonant technique and a non-contacting periodic permanent magnet electromagnetic acoustic transducer (PPMEMAT). The PPM-EMAT consists of hollowed cylindrical shape permanent magnet units wound around by a transmission coil and a reception coil. In the case of EMAT for the axial shear wave, it consists of a solenoidal coil in order to apply a static field along the finned tube and propagate the axial shear wave along the circumference of the finned tube with axial polarization. It is clarified that EMAR wave technique is the best corrosion detection tool for finned tubes in air-cooled exchangers.

収録刊行物

  • 非破壊検査

    非破壊検査 59 (7), 334-339, 2010

    一般社団法人 日本非破壊検査協会

被引用文献 (1)*注記

もっと見る

参考文献 (11)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ